VGP404/ 710-1500KVA Brushless Synchronous Alternator
    DIYPOWER VGP ALTERNATOR

     VGP~404 Series
     
710-1500 KVA


      Brushless Synchronous Alternator

Rated Date 50Hz - 1500 RPM
Rating kVA/ kW cos Φ=0.8
Duty/Ambient T °  Continuous/ 40℃ Stand by/27℃
Ins. Class/ T  ° Rise H / 125 ° K H/163° K
Phase 3 Phase 3 Phase
Voltage Y 380V 400V 415V 440V 380V400V415V440V
YY* 190V 200V 208V 220V 190V200V208V 220V
△* 220V 230V 240V 254V 220V 230V 240V 254V 

VGP404S1

KVA 710750750680
825

kW 568600600544
660

VGP404S2

KVA 760800800725
880

kW 608640640580
704

VGP404S3

KVA 865910910825
1000

kW 692728728660
800

VGP4004S4 KVA 95010001000910
1100

kW 760800800728
880

VGP404S5 KVA 1075113011301025
1265

kW 860904904820
1012

VGP404M6 KVA 1190125012501135
1375

kW 95210001000908
1100

VGP404M7 KVA 1310137513751275
1512.5

kW 1048110011001020
1210

VGP404M8 KVA 1425150015001375
1650

kW 1140120012001100
1320


Rated Date60Hz - 1800 RPM
RatingkVA/ kW cos Φ=0.8
Duty/Ambient T ° Continuous/ 40℃Stand by/27℃
Ins. Class/ T  ° RiseH / 125 ° KH/163° K
Phase3 Phase3 Phase
VoltageY416V440V460V480V416V440V460V480V
YY*208V220V230V240V208V220V230V240V
△*240V524V266V277V240V524V266V277V

VGP404S1

KVA810855895937.5

1000
kW648684716750

800

VGP404S2

KVA865916.3957.51000

1075
kW692733766800

860

VGP404S3

KVA986.251053.7510901137.5

1250
kW789843872910

1000
VGP404S4KVA1082.511451197.51250

1350
kW8669169581000

1080
VGP404S5 KVA 1203.751273.81332.51390

1500
kW 963101910661112

1200
VGP404M6 KVA 13101386.31448.81512.5

1650
kW 1048110911591210

1320
VGP404M7 KVA 1387.5145015001625

1762.5
kW 1110116012001300

1410
VGP404M8 KVA 1487.5162517251875

1875
kW 1190130013801500

1500 
ENVIRONMENT CONDITIONS:
In the following environments, the alternator could run continuously:
1. Altitude: do not exceed 1000m.
2. Cooling air temperature: 250~313K (-15℃~40℃).
3. Relative air humidity: do not exceed 90%.
Note: If environment conditions exceed the scope mentioned-above, please feel free to contact us.
MAIN PERFORMACE DATA:
1.    The standard protection for VGP series generators is IP23;
2.  Winding are insulated to class H;
3.  Full-damping whole salient construction guarantees generator to be operated stably in any conditions, and enable it to run under 150% rated speed(2250 r/min) for 2 minutes;
4.   VGP alternator are provided with a 2/3 winding pitch as standard, can effectively eliminated the third harmonic (3rd, 9th, 15th …etc.), and are therefore perfectly suited to installations with distorting loads, and easy to operate with the other alternator in parallel;
5.  Adjusting rate of stable voltage ≤ 1%, adjusting rate of instant voltage: -15%~+20% (60&ln, COSΦ ≤ 0.4 lagging), instant voltage recovery time ≤ 1.5s;
6.  Wave aberration rate of voltage THD ≤ 3%, telephone harmony wave factor THF ≤ 2%, telephone effective factor of TIF≤ 50.



| Send Inquiry | Global Distributor | Contact Us | Email Login | Home

© 1996-2015 DIY POWER SYSTEM