VGP354/ 450-887.5KVA Brushless Synchronous Alternator
    DIYPOWER VGP ALTERNATOR

     VGP~354 Series
     
450-887.5 KVA 


      Brushless Synchronous Alternator

Rated Date 50Hz - 1500 RPM
Rating kVA/ kW cos Φ=0.8
Duty/Ambient T °  Continuous/ 40℃ Stand by/27℃
Ins. Class/ T  ° Rise H / 125 ° K H/163° K
Phase 3 Phase 3 Phase
Voltage Y 380V 400V 415V 440V 380V 400V 415V 440V
220V 230V 240V
220V 230V 240V
YY


220V


220V

VGP354S1

KVA 450450450450487.5487.5487.5487.5
kW 360360360360390390390390

VGP354S2

KVA 500500500487.5531.3531.3531.3518.8
kW 400400400390425425425415

VGP354S3

KVA 552.5562.5552.5512.5572.5590575557.5
kW 442450442410458472460446
VGP354S4 KVA 588.8600588.8550612.5630615595
kW 471480471440490504492476
VGP354M5 KVA 615625615575632.5652.5635617.5
kW 492500492460506522508494
VGP354M6 KVA 637.5650637.5600655675657.5640
kW 510520510480524540526512
VGP354M7 KVA 662.5675662.5622.5675695677.5657.5
kW 530540530498540556542526
VGP354L8 KVA 685700685645697.5718.8700677.5
kW 548560548516558575560542

Rated Date60Hz - 1800 RPM
RatingkVA/ kW cos Φ=0.8
Duty/Ambient T ° Continuous/ 40℃Stand by/27℃
Ins. Class/ T  ° RiseH / 125 ° KH/163° K
Phase3 Phase3 Phase
VoltageY380V416V440V480V380V416V440V480V
220V240V

220V240V220V
YY
208v220V240V


240V

VGP354S1

KVA477.5500520540517.5530550581.3
kW382400416432414424440465

VGP354S2

KVA530552.5575600570587.5610645
kW424442460480456470488516

VGP354S3

KVA597.5620645675637.5657.5682.5715
kW478496516540510526546572
VGP354S4KVA637.5660687.5720677.5700727.5765
kW510528550576542560582612
VGP354M5 KVA 660687.5712.5750707.5730757.5797.5
kW 528550570600566584606638
VGP354M6 KVA 700722.5745780747.5770797.5837.5
kW 560578596624598616638670
VGP354M7 KVA 727.5750775810770790817.5852.5
kW 582600620648616632654682
VGP354L8 KVA 757.5780802.5840802.5822.5852.5887.5
kW 606621642672642658682710
ENVIRONMENT CONDITIONS:
In the following environments, the alternator could run continuously:
1. Altitude: do not exceed 1000m.
2. Cooling air temperature: 250~313K (-15℃~40℃).
3. Relative air humidity: do not exceed 90%.
Note: If environment conditions exceed the scope mentioned-above, please feel free to contact us.
MAIN PERFORMACE DATA:
1.    The standard protection for VGP series generators is IP23;
2.  Winding are insulated to class H;
3.  Full-damping whole salient construction guarantees generator to be operated stably in any conditions, and enable it to run under 150% rated speed(2250 r/min) for 2 minutes;
4.   VGP alternator are provided with a 2/3 winding pitch as standard, can effectively eliminated the third harmonic (3rd, 9th, 15th …etc.), and are therefore perfectly suited to installations with distorting loads, and easy to operate with the other alternator in parallel;
5.  Adjusting rate of stable voltage ≤ 1%, adjusting rate of instant voltage: -15%~+20% (60&ln, COSΦ ≤ 0.4 lagging), instant voltage recovery time ≤ 1.5s;
6.  Wave aberration rate of voltage THD ≤ 3%, telephone harmony wave factor THF ≤ 2%, telephone effective factor of TIF≤ 50. 