VGP184/ 18.75-55KVA Brushless Synchronous Alternator
    DIYPOWER VGP ALTERNATOR

     VGP~184 Series
     
18.75-55 KVA

      Brushless Synchronous Alternator

Rated Date 50Hz - 1500 RPM
Rating kVA/ kW cos Φ=0.8
Duty/Ambient T °  Continuous/ 40℃ Stand by/27℃
Ins. Class/ T  ° Rise H / 125 ° K H/163° K
Phase 3 Phase 3 Phase
Voltage Y 380V 400V 415V 440V 380V 400V 415V 440V
220V 230V 240V
220V 230V 240V
YY

  220V


220V

VGP184S5

KVA 18.75 18.75 18.75 18.75 21.5 21.5 21.5 21.5
kW 15 15 15 15 17.2 17.2 17.2 17.2

VGP184M6

KVA 22.5 22.522.522.5 26.5 26.5 26.5 26.5
kW 18 181818 21.2 21.2 21.2 21.2

VGP184M7

KVA 25 25 25 25 29 29 29 29
kW 20 20 20 20 23.2 23.2 23.2 23.2
VGP184M8 KVA 27.5 27.5 27.5 27.5 32 32 32 32
kW 22 22 22 22 25.6 25.6 25.6 25.6
VGP184L9 KVA 31.25 31.25 31.25 31.25 36.5 36.5 36.5 36.5
kW 25 25 25 25 29.2 29.2 29.2 29.2
VGP184L10 KVA 37.5 37.5 37.5 37.5 42.5 42.5 42.5 42.5
kW 30 30 30 30 34 34 34 34

Rated Date60Hz - 1800 RPM
RatingkVA/ kW cos Φ=0.8
Duty/Ambient T ° Continuous/ 40℃Stand by/27℃
Ins. Class/ T  ° RiseH / 125 ° KH/163° K
Phase3 Phase3 Phase
VoltageY380V416V440V480V380V416V440V480V
220V240V 
220V240V220V
YY
208v220V240V


240V

VGP184S5

KVA1920.52223.522.524.525.528
kW15.216.417.618.81819.620.422.4

VGP184M6

KVA25.7527.528.753028.2530.6331.2533.13
kW20.622232422.624.52526.5

VGP184M7

KVA28.133031.2532.530.7533.1333.7535.63
kW22.524252624.626.52728.5
VGP184M8KVA30.532.534.383533363841
kW24.42627.52826.428.830.432.8
VGP184L9 KVA 31.53537.537.537.5414646
kW 25.22830303032.836.836.8
VGP184L10 KVA 41.2544.2546.8846.8845495555
kW 3335.437.537.53639.24444
ENVIRONMENT CONDITIONS:
In the following environments, the alternator could run continuously:
1. Altitude: do not exceed 1000m.
2. Cooling air temperature: 250~313K (-15℃~40℃).
3. Relative air humidity: do not exceed 90%.
Note: If environment conditions exceed the scope mentioned-above, please feel free to contact us.
MAIN PERFORMACE DATA:
1.    The standard protection for VGP series generators is IP23;
2.  Winding are insulated to class H;
3.  Full-damping whole salient construction guarantees generator to be operated stably in any conditions, and enable it to run under 150% rated speed(2250 r/min) for 2 minutes;
4.   VGP alternator are provided with a 2/3 winding pitch as standard, can effectively eliminated the third harmonic (3rd, 9th, 15th …etc.), and are therefore perfectly suited to installations with distorting loads, and easy to operate with the other alternator in parallel;
5.  Adjusting rate of stable voltage ≤ 1%, adjusting rate of instant voltage: -15%~+20% (60&ln, COSΦ ≤ 0.4 lagging), instant voltage recovery time ≤ 1.5s;
6.  Wave aberration rate of voltage THD ≤ 3%, telephone harmony wave factor THF ≤ 2%, telephone effective factor of TIF≤ 50. 