VGP164/ 6.25-22KVA Brushless Synchronous Alternator
    DIYPOWER VGP ALTERNATOR

   VGP~164 Series 
     6.25-22 KVA 

      Brushless Synchronous Alternator

Rated Date 50Hz - 1500 RPM
Rating kVA/ kW cos Φ=0.8
Duty/Ambient T °  Continuous/ 40℃ Stand by/27℃
Ins. Class/ T  ° Rise H / 125 ° K H/163° K
Phase 3 Phase 3 Phase
Voltage Y 380V 400V 415V 440V 380V 400V 415V 440V
220V 230V 240V
220V 230V 240V
YY

  220V


220V

VGP164VS1

KVA 6.25 6.25 6.25 6.25 7.875 7.875 7.875 7.875
kW 5 5 5 5 6.3 6.3 6.3 6.3

VGP164VS2

KVA 9.375 9.375 9.375 9.375 11.13 11.13 11.13 11.13
kW 7.5 7.5 7.5 7.5 8.9 8.9 8.9 8.9

VGP164VS3

KVA 12.5 12.5 12.5 12.5 14.5 14.5 14.5 14.5
kW 10 10 10 10 11.6 11.6 11.6 11.6
VGP164S4 KVA 15 15 15 15 17.5 17.5 17.5 17.5
kW 12 12 12 12 14 14 14 14

Rated Date60Hz - 1800 RPM
RatingkVA/ kW cos Φ=0.8
Duty/Ambient T ° Continuous/ 40℃Stand by/27℃
Ins. Class/ T  ° RiseH / 125 ° KH/163° K
Phase3 Phase3 Phase
VoltageY380V416V440V480V380V416V440V480V
220V240V 
220V240V220V
YY
208v220V240V


240V

VGP164VS1

KVA6.57.58.138.1388.59.759.75
kW5.266.56.56.46.87.87.8

VGP164VS2

KVA1010.512121212.514.1314.13
kW88.49.69.69.61011.311.3

VGP164VS3

KVA12.51415.6315.6315.517.2518.518.5
kW1011.212.512.512.413.814.814.8
VGP164S4KVA16.2517.5191919.2521.252222
kW131415.215.215.41717.617.6
ENVIRONMENT CONDITIONS:
In the following environments, the alternator could run continuously:
1. Altitude: do not exceed 1000m.
2. Cooling air temperature: 250~313K (-15℃~40℃).
3. Relative air humidity: do not exceed 90%.
Note: If environment conditions exceed the scope mentioned-above, please feel free to contact us.
MAIN PERFORMACE DATA:
1.    The standard protection for VGP series generators is IP23;
2.  Winding are insulated to class H;
3.  Full-damping whole salient construction guarantees generator to be operated stably in any conditions, and enable it to run under 150% rated speed(2250 r/min) for 2 minutes;
4.   VGP alternator are provided with a 2/3 winding pitch as standard, can effectively eliminated the third harmonic (3rd, 9th, 15th …etc.), and are therefore perfectly suited to installations with distorting loads, and easy to operate with the other alternator in parallel;
5.  Adjusting rate of stable voltage ≤ 1%, adjusting rate of instant voltage: -15%~+20% (60&ln, COSΦ ≤ 0.4 lagging), instant voltage recovery time ≤ 1.5s;
6.  Wave aberration rate of voltage THD ≤ 3%, telephone harmony wave factor THF ≤ 2%, telephone effective factor of TIF≤ 50. 